How Far Can a Deck Beam Span?
Use the 2018 IRC to size deck beams and calculate beam span.
Sizing deck beams got a lot easier with the publication of the 2015 International Residential Code. Deck builders can now refer to Section R507.6 Deck Beams and Table R507.6 Deck Beam Span Lengths to determine the size of 2-ply and 3-ply built-up beams made from 2×6 through 2×12 lumber. These values didn’t change in the 2018 version of the IRC. (For more on other aspects of framing an elevated deck, have a look at this guide.)
The beam spans are based on the span of the deck joists, which are listed in 2 ft. increments from 6 ft. through 18 ft. Although the practice is common, there’s no allowance for interpolating beam spans when the joist length you’re dealing with isn’t listed in the table. For example, a double 2×8 beam can span 8-ft.-9 in. when the deck joists are 6 ft. long. When the deck joists are 8 ft. long, the beam can span 7-7. When building a deck with 7-ft. joists, you know the beam can span somewhere between 7-7 and 8-0, but you don’t know exactly where. Check with your local code official, or simply drop back to the shorter value in the table and assume the allowable span is 7-7.
Fastening and Cantilevering
Section R507.6 calls for the built-up beams to be fastened together with a minimum of 10d nails spaced 16 in. on-center along both edges. Joints in beam layers must fall over posts.
Beams are permitted to cantilever past the end posts up to one-quarter of the beam span between posts. I like to use this provision when sizing beams. Often I can reduce the span between posts slightly by cantilevering the beam. This allows me to make the beam a little smaller (by dropping, say, from a double 2×10 to a double 2-2×8). Beam span and cantilever measurements are taken from the center of the posts, not the face of the posts.
More to Consider
There are other beam provisions and limitations in the 2015 IRC to take note of:
- Beam ends must bear at least 1 1/2 in. on wood or metal and 3 in. on concrete or masonry.
- Beams must be attached to posts using either post cap hardware or a notched leg of the post.
- The beam table is limited to 10 psf. dead load and 40 psf. live / snow load.
Even if your local code jurisdiction hasn’t adopted the 2015 IRC, most building officials will look favorably on an ICC sanctioned code provision. So run the table by your building official for approval before using it.
- Ultimate Deck Build: Building and Leveling a Beam
- Installing Deck Beams
- Build a Grade-Level Deck: Install Posts and Rim Beam
This post contains affiliate links, which means Fine Homebuilding may receive a small commission, at no cost to you, if you make a purchase through a link. As an Amazon Associate we earn from qualifying purchases.
Fine Homebuilding Recommended Products
Fine Homebuilding receives a commission for items purchased through links on this site, including Amazon Associates and other affiliate advertising programs.
Graphic Guide to Frame Construction
Musings of an Energy Nerd: Toward an Energy-Efficient Home
A Field Guide to American Houses