Energy Codes as Clear as Glass

The building codes for windows address both thermal and air transmission—here's what you need to know to select windows using the prescriptive path.

By Glenn Mathewson Issue 299 - June 2021
  • X
  • facebook
  • linkedin
  • pinterest
  • email
  • add to favorites Log in or Sign up to save your favorite articles

Synopsis: Whether windows are required or provided by choice, the code has long-addressed various safety concerns. With the rising importance of energy conservation, it has added requirements to manage the energy penalties that can come with them. In this column, building-code expert Glenn Mathewson addresses the paths to code compliance.


If not for local ordinances that would likely prohibit it, you could, in some half-baked pursuit of energy efficiency, build a house with no windows— the 2021 International Residential Code (IRC) won’t stand in your way (and people say the code is restrictive!). You couldn’t have done this in the 1800s, though. Before electric light was allowed as an exception, windows were required in order to provide natural light and reduce the use of candles and lanterns during daylight hours (largely to reduce fire risk). More recently, the need for windows to provide ventilation has been circumvented by the introduction of whole-house ventilation systems.

Whether windows are required or provided by choice, the code has long-addressed various safety concerns, from safety glazing in hazardous locations to emergency escape and rescue openings (EEROs). With the rising importance of energy conservation, it has added requirements to manage the energy penalties that can come with them.

Paths to code compliance

The energy crisis of the late ’70s brought energy-efficiency considerations to many aspects of building, including window-code provisions. Though they have evolved, window-efficiency requirements today address the same two subjects originally targeted in the code: thermal transmission and air leakage. One requirement that was later added and then dropped is window-to-wall ratio. Just as you can build a windowless house, you can also build an all-window house. This makes sense on a couple levels. For one, windows have improved dramatically and can conceivably perform better than walls in some designs (for an example of this, see “Trombe Wall Solution”). More importantly, the code is designed to address the probable, not the possible. The free market will take care of outliers like all-glass houses.

window ratings label
Check the label. The ratings labels on factory-built windows provide the performance data needed to comply with the energy code’s prescriptive window requirements.

Unlike other parts of the code that are largely aimed at protecting life and limb within the well-established goals, practices, and assemblies of architecture and construction, the energy-code provisions started out as outliers. They were located in optional “appendix” chapters and specialized books, and for acceptance, they needed to be flexible in their application. It’s convenient that they are bound in scientific and mathematical principles, as this allows different methods of code compliance to be compared against each other in near equivalency. In short, energy codes are full of options. Values discussed in this article are for the “prescriptive” method, where you simply have to meet minimum requirements for each performance characteristic.

From those values, however, the performance of individual features can be traded to yield an overall equivalency, such as a higher R-value in the ceiling insulation coupled with lower-performing windows. Similarly, another method allows the estimated cost of energy consumption attributed to various subjects to be flexible, provided the sum of cost is less than a standardized estimate. This method could allow for lower-performing windows to be offset by a high-performance heating system, for example. Altogether, the energy code provides four (or more, depending on how you count) different paths to get to the code’s minimum-required efficiencies, and with the ability to mix and match assemblies and components, and even use different compliance paths for different assemblies within the same home, there are more ways to meet code for any one home than we could even begin to cover here. Here’s what you need to know to select windows using the prescriptive path.

Thermal transmission

Windows are evaluated not by R-value—the resistance to heat movement—but by U-factor, which measures heat transmission. This is a mathematical relationship, where U-factor is the reciprocal of R-value (1 / R-value = U-factor). A lower U-factor in a window is like a higher R-value in a wall. Just as the minimum R-value increases in colder climates, the maximum-allowed U-factor decreases in cold climates. Lumped together with doors under the word “fenestration,” IRC Table N1102.1.2 provides maximum U-factors (minimum performance) between 0.50 and 0.30 for climate zones 1 (warm) through 8 (cold).

U-factor only measures the non-solar-heat movement through the window assembly. Essentially, it measures heat lost from indoor air to the outside when it’s cold out, and heat gained from outdoor air when it’s hot. Though cooling is not required by the code in the way heating is, warmer climate zones still have requirements to limit the heat gain via solar radiation through the window. The solar-heat-gain coefficient (SHGC) is like the U-factor in that the lower the value, the less solar radiation the window transmits inside. The same table referenced previously provides maximum SHGCs from 0.25 to 0.40 for climate zones 1 through 4. In colder climates, there is no SHGC requirement, as the warm sun is typically welcome in the heating season and can improve a home’s overall energy efficiency.

As in nearly all code subjects, there are exceptions that address specific considerations. For example, one might want a fancy glass front door, or a window that incorporates Grandpa’s stained glass from the old family homestead. Just as provisions for safety glazing have exceptions for decorative glazing (stained glass), so does the energy code. Not specific to decorative glazing, Section N1102.3.3 allows up to 15 sq. ft. of glazing to be exempt from all U-factor and SHGC requirements in each dwelling. Additionally, Section N1102.3.4 exempts a single opaque door, often used for a front door, from these requirements.

Air transmission

Heat can bypass all the units of measurement we’ve discussed thus far when traveling through a gap on a current of air. Factory-built windows must be laboratory tested to meet code minimums for air leakage. A window can have no greater air infiltration than 0.3 cfm per sq. ft. in accordance with the NFRC 400 standard from the National Fenestration Rating Council or with the AAMA/WDMA/CSA 101/I.S.2/A440 standard from the— what? Never mind. Large and ornate main-level, street-facing windows could be lower performing to reduce costs, while being offset by higher-performing but basic bedroom windows.

For the majority of mainstream manufactured windows, the title of that standard won’t matter. The various values and test listings of energy-code compliance are provided on the label adhered to each window, typically an NFRC label. It’s a good idea to leave those labels on the windows until after you get a final inspection. You won’t need labels, though, for site-built windows such as the stained glass you moved from the farmhouse. Site-built windows are excepted from air-leakage requirements [though not from U-factor and SHGC requirements—without testing, they’re assigned default values based on the type of construction, given in Tables N1101.10.3(1) through N1101.10.3(3)]. For new construction, subject to maximum air-leakage rates verified by blower-door tests, leaky site-built windows will be revealed and will have to be offset by tighter construction elsewhere or repaired.

Window replacements

Though I often use automobile standards as a comparison to building-code standards, the analogy falls apart when discussing repairs and rebuilds. You can’t rebuild a house to old standards like you can a car. Full window replacements (not simply reglazing a broken pane), must meet the same standards as new construction for U-factor, SHGC, and air leakage— but as always, there are options. When more than one window is replaced, an area-weighted average of all the windows can be taken for both U-factor and SHGC. This allows for higher-performing windows to offset lower-performing windows. Large and ornate main-level, street-facing windows could be lower performing to reduce costs, while being offset by higher-performing but basic bedroom windows. This design option can also be utilized in new construction using prescriptive methods without trading assemblies or evaluating energy costs. The intent is to provide maximum design and cost-analysis freedom.

Though not related to the energy code, emergency escape and rescue openings (EEROs) must be addressed when discussing window replacements. Replacement windows that fit inside existing frames often reduce the size of the clear opening below the minimum size typically required for an EERO. Inspectors have been known to derail window replacements on these grounds. However, the IRC has taken a larger look at this and allows replacements that may reduce the opening size, provided they are the largest standard size the manufacturer makes for the rough opening and either the same style or a style with a larger opening.

Though on paper this may appear to reduce safety, in reality, many older windows are very difficult to operate, have broken latches, or are sealed completely shut. In other words, old windows can have more problems than just energy loss. A new window with easy, smooth, and functional operation may yield a slightly smaller opening, but may ultimately offer more safety in addition to better energy efficiency.

 

Glenn Mathewson is a consultant and educator with buildingcodecollege.com.

Photo: Brian McAward

From Fine Homebuilding #299


RELATED LINKS

  • What’s the Difference: Energy-Efficient Windows
  • Demystifying Window Labels – SHGC? U-Factor?
  • Insulating Glass Keeps Getting Better
Previous: Should I Replace My Old Windows?

Guide

Windows & Doors

Chapter

Choosing Windows

Sign up for eletters today and get the latest how-to from Fine Homebuilding, plus special offers.

Signing you up...

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
See all newsletters
See all newsletters

Log in or create an account to post a comment.

Sign up Log in

Become a member and get full access to FineHomebuilding.com

Windows & Doors

Windows & Doors

Trusted, comprehensive guidance from the pros for choosing, installing, replacing, and repairing windows and doors on any house

View Project Guide

View All Project Guides »

Become a member and get unlimited site access, including the Windows & Doors Project Guide.

Start Free Trial

Choosing Windows
  • Window Types
  • Design and Materials
  • Energy-Efficient Windows
Installing Windows In New Walls
  • Installation, Start to Finish
  • Head Flashing for Windows
  • Video Series: Nail-Fin Window over Zip System Sheathing
  • Video Series: Nail-Fin Window over Exterior Rigid-Foam Insulation
  • Video Series: Nail-Fin Window over Housewrap
  • Video Series: Nail-Fin Window over Peel-and-Stick Housewrap
  • Video Series: Nail-Fin Window over a Fluid-Applied WRB
  • Video Series: Weatherproof Window Installation
Retrofitting Windows
  • Removing the Old, Installing the New
  • Video Series: How to Replace a Window
  • Video Series: Install a Full-Frame Replacement Window in a Brick Wall
  • Video Series: Install an Insert Replacement Window in a Brick Wall
  • Video Series: Retrofit a Flanged Window
Window Repairs
  • Restoring Old Windows
  • Repairs and Upgrades
Door Basics
  • Tools & Jigs for Door Hanging
  • How to Install Doors
  • Hinges
  • Handles, Knobs, and Locksets
  • Fixing Door Problems
Interior Doors
  • Prehung Doors
  • Pocket Doors
  • Other Types of Doors
  • Custom-Built Doors
Exterior Doors
  • Door Choices and Design
  • Installing Entry Doors
  • Building Exterior Doors
  • Installing French Doors
  • Replacing a Door
  • Adding Weatherstripping and Sweeps

Fine Home Building

Newsletter Sign-up

  • Fine Homebuilding

    Home building tips, offers, and expert advice in your inbox.

  • Green Building Advisor

    Building science and energy efficiency advice, plus special offers, in your inbox.

  • Old House Journal

    Repair, renovation, and restoration tips, plus special offers, in your inbox.

Signing you up...

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
See all newsletters

Follow

  • Fine Homebuilding

    Dig into cutting-edge approaches and decades of proven solutions with total access to our experts and tradespeople.

    Start Free Trial Now
    • Facebook
    • Instagram
    • X
    • LinkedIn
  • GBA Prime

    Get instant access to the latest developments in green building, research, and reports from the field.

    Start Free Trial Now
    • Facebook
    • YouTube
  • Old House Journal

    Learn how to restore, repair, update, and decorate your home.

    Subscribe Now
    • Facebook
    • Instagram
    • X
  • Fine Homebuilding

    Dig into cutting-edge approaches and decades of proven solutions with total access to our experts and tradespeople.

    Start Free Trial Now
    • Facebook
    • Instagram
    • X
    • LinkedIn
  • GBA Prime

    Get instant access to the latest developments in green building, research, and reports from the field.

    Start Free Trial Now
    • Facebook
    • YouTube
  • Old House Journal

    Learn how to restore, repair, update, and decorate your home.

    Subscribe Now
    • Facebook
    • Instagram
    • X

Membership & Magazine

  • Online Archive
  • Start Free Trial
  • Magazine Subscription
  • Magazine Renewal
  • Gift a Subscription
  • Customer Support
  • Privacy Preferences
  • About
  • Contact
  • Advertise
  • Careers
  • Terms of Use
  • Site Map
  • Do not sell or share my information
  • Privacy Policy
  • Accessibility
  • California Privacy Rights

© 2025 Active Interest Media. All rights reserved.

Fine Homebuilding receives a commission for items purchased through links on this site, including Amazon Associates and other affiliate advertising programs.

  • Home Group
  • Antique Trader
  • Arts & Crafts Homes
  • Bank Note Reporter
  • Cabin Life
  • Cuisine at Home
  • Fine Gardening
  • Fine Woodworking
  • Green Building Advisor
  • Garden Gate
  • Horticulture
  • Keep Craft Alive
  • Log Home Living
  • Military Trader/Vehicles
  • Numismatic News
  • Numismaster
  • Old Cars Weekly
  • Old House Journal
  • Period Homes
  • Popular Woodworking
  • Script
  • ShopNotes
  • Sports Collectors Digest
  • Threads
  • Timber Home Living
  • Traditional Building
  • Woodsmith
  • World Coin News
  • Writer's Digest
Active Interest Media logo
X
X
This is a dialog window which overlays the main content of the page. The modal window is a 'site map' of the most critical areas of the site. Pressing the Escape (ESC) button will close the modal and bring you back to where you were on the page.

Main Menu

  • How-To
  • Design
  • Tools & Materials
  • Video
  • Blogs
  • Forum
  • Project Guides
  • Reader Projects
  • Magazine
  • Members
  • FHB House

Podcasts

  • FHB Podcast
  • ProTalk

Webinars

  • Upcoming and On-Demand

Podcasts

  • FHB Podcast
  • ProTalk

Webinars

  • Upcoming and On-Demand

Popular Topics

  • Kitchens
  • Business
  • Bedrooms
  • Roofs
  • Architecture and Design
  • Green Building
  • Decks
  • Framing
  • Safety
  • Remodeling
  • Bathrooms
  • Windows
  • Tilework
  • Ceilings
  • HVAC

Magazine

  • Current Issue
  • Past Issues
  • Magazine Index
  • Subscribe
  • Online Archive
  • Author Guidelines

All Access

  • Member Home
  • Start Free Trial
  • Gift Membership

Online Learning

  • Courses
  • Project Guides
  • Reader Projects
  • Podcast

More

  • FHB Ambassadors
  • FHB House
  • Customer Support

Account

  • Log In
  • Join

Newsletter

Get home building tips, offers, and expert advice in your inbox

Signing you up...

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
See all newsletters
See all newsletters

Follow

  • X
  • YouTube
  • instagram
  • facebook
  • pinterest
  • Tiktok

Join All Access

Become a member and get instant access to thousands of videos, how-tos, tool reviews, and design features.

Start Your Free Trial

Subscribe

FHB Magazine

Start your subscription today and save up to 70%

Subscribe

This is your last free article.

Don't miss another expert tip or technique from building pros. Start your free trial today.

Start your FREE trial

Already a member? Log in

We hope you’ve enjoyed your free articles. To keep reading, become a member today.

Get complete site access to expert advice, how-to videos, Code Check, and more, plus the print magazine.

Start your FREE trial

Already a member? Log in

Privacy Policy Update

We use cookies, pixels, script and other tracking technologies to analyze and improve our service, to improve and personalize content, and for advertising to you. We also share information about your use of our site with third-party social media, advertising and analytics partners. You can view our Privacy Policy here and our Terms of Use here.

Cookies

Analytics

These cookies help us track site metrics to improve our sites and provide a better user experience.

Advertising/Social Media

These cookies are used to serve advertisements aligned with your interests.

Essential

These cookies are required to provide basic functions like page navigation and access to secure areas of the website.

Delete My Data

Delete all cookies and associated data